EPS foam blast attenuation in full-scale field test of reinforced concrete slabs
Authors
Acta Scientiarum Technology , vol. 42 , no. 1 , Article e40020
ISSN: 18062563
Abstract
© 2020, Eduem - Editora da Universidade Estadual de Maringa. All rights reserved.Predicting explosion parameters is an important step when planning for blast tests or the design of blast resistant buildings. This paper presents a comparison of recorded pressure that was reflected on the surface of reinforced concrete slabs with and without EPS (Expanded Polystyrene) foam retrofit measured from a detonation of 2.7 kg of non-confined plastic explosive. Two 50 MPa reinforced concrete slabs measuring 1.0×1.0×0.08 m, simply supported on two sides were tested. The explosive was suspended at a distance of 2.0 m from the upper surface of the slabs; one of the slabs had 5.0 cm thick foam on the top side. Eight piezoelectric pressure sensors were positioned at a distance of 2.0 m from the explosive. Results showed that the foam retrofit reduced the reflected pressure by approximately 57% when compared to the slab without EPS foam retrofit.
Keywords
2-s2.0-85074698593