PG-EAM - Programa de Pós-Graduação em Engenharia Aeronáutica e Mecânica
EN PT
Artigo 2020

EPS foam blast attenuation in full-scale field test of reinforced concrete slabs

Autores

Mendonça, Fausto Batista
Urgessa, Girum Solomon
Dutra, Rita Lazzarini
Iha, Koshun

Acta Scientiarum Technology , vol. 42 , no. 1 , Article e40020

ISSN: 18062563

8
Citações
6
Autores

Resumo

© 2020, Eduem - Editora da Universidade Estadual de Maringa. All rights reserved.Predicting explosion parameters is an important step when planning for blast tests or the design of blast resistant buildings. This paper presents a comparison of recorded pressure that was reflected on the surface of reinforced concrete slabs with and without EPS (Expanded Polystyrene) foam retrofit measured from a detonation of 2.7 kg of non-confined plastic explosive. Two 50 MPa reinforced concrete slabs measuring 1.0×1.0×0.08 m, simply supported on two sides were tested. The explosive was suspended at a distance of 2.0 m from the upper surface of the slabs; one of the slabs had 5.0 cm thick foam on the top side. Eight piezoelectric pressure sensors were positioned at a distance of 2.0 m from the explosive. Results showed that the foam retrofit reduced the reflected pressure by approximately 57% when compared to the slab without EPS foam retrofit.

Palavras-chave

Blast test Expanded polystyrene Non-confined plastic explosive Pressure reduction Reflected pressure

Computer Science (all) (COMP) Chemistry (all) (CHEM) Mathematics (all) (MATH) Engineering (all) (ENGI) Physics and Astronomy (all) (PHYS) Earth and Planetary Sciences (all) (EART)
: Scopus
Última atualização: 2026-06-25
: 2-s2.0-85074698593